MegaLite Axis Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 17
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
50 mm
7 mm
5 mm
Anchor alignment
15 mm
45 mm
4 5
3
241 6 9
10 cm
5 cm
5 cm
20 cm
55 cm
77,5 cm
32,5 cm
0 cm
100 cm
122,5 cm
145 cm
167,5 cm
190 cm
195 cm
7
10
8
Installation procedure
Sub-structure
1. Make the foundation width and depth
following static requirements and install
frost-free. Recommended: 40 × 40 cm and
80 cm depth.
2. The maximum distance between the axes
of the posts of a straight fence field is 200 cm.
Covering a corner it may be up to 206 cm.
3. Observe the position of the posts for
alignment of the screw-on/concrete-moun-
ted anchors.
4. Position screw-on and concrete-mounted
anchors in a way that the post mounting has
at least 5 cm distance from the accumulated
gravel (or ground) and 10 cm to the upper edge
of the foundation. Avoid ground contact of
the megawood
®
visual protection.
Installation
5. For fastening the posts, take hole
distances from the fastening anchor and
transfer them to the posts. Then, drill
through with a 12 mm metal drill and
countersink the holes. Push posts onto the
anchor and fix with non-corroding screws.
6. To fasten the wall cover afterwards, a
slit must be sawed into the groove at the
top of the post with a width of 7 mm and a
depth of 50 mm.
7. Glue in sealing tape into the groove
from below until it almost reaches the slit.
Later, this will fill the post joint and fix the
visual protection elements, so that the
visual protection element can expand freely.
8. After that, immediately push in the
visual protection boards from the top into
the post groove. Ensure that the installation
direction is consistent (printed arrow in the
visual protection groove).
9. Shorten wall cover by 4 cm vis-à-vis
the length of the visual protection boards.
Then screw fastening plate and wall cover
together. After that, it is inserted into the
sawed-out groove and screwed on. For this,
keep a distance of 20 mm between the
upper edge of the wall cover and the upper
edge of the post.
10. Plug post caps onto the post, if
necessary use silicone glue for fixing.
STANDARD
VISUAL PROTECTION
Distance between axes
max. 200 cm
Distance between axes
max. 203 cm
Distance between axes
max. 206 cm
PRODUCT
OVERVIEW
29 28
STANDARD visual protection board
25 × 232 mm | L: 193 cm
STANDARD post
100 × 160 mm | L: 190 cm
STANDARD fastening plate
for wall cover, incl. nuts
Design: Stainless steel
STANDARD sealing tape
Up to 20 mm expanding | L: 8 m
(on roll)
STANDARD post cap
Decorative cap with globe
100 × 160 mm
Designs: Stainless steel / zinc coated
STANDARD post cap
Decorative cap without globe
100 × 160 mm
Designs: Stainless steel / zinc coated
STANDARD screw-on anchor
85 × 93 mm | L: 40 cm
(220 × 160 mm base plate)
Design: Hot-galvanized
STANDARD concrete-mounted anchor
85 × 93 mm | L: 80 cm
Design: Hot-galvanized
STANDARD wall cover
50 × 85 mm | L: 189 cm
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17

Comentários a estes Manuais

Sem comentários