Cleaning and maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electron-
ics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts like axles, eyes and other must not show any traces of wearing and must not rotate with unbal-
ances.
4) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further
instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems
have to be removed.
Disconnect from mains before starting maintenance operation!
Caution Danger to life!
We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or solvents!
1) The objective lens will require periodic cleaning on usage and environment. Environment with foggers will require more peri-
odic cleaning as fog fluid tends to build up residues, reducing the light output.
2) The cooling-fans should be cleaned monthly. DO NOT blow high pressure air into fans as incorrect rotation can damage the
fans operation.
3) The gobos, dichroic color filters and internal lenses may be cleaned with soft brush using soapy water.
4) The interior of the fixture should be cleaned using a vacuum.
5) We recommend proper lubrication of the motor wheel. The quantity of the oil must not be excessive in order to avoid oil run
outs when motor wheel rotates
Note: There is no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service operations are
to be carried out by authorized dealers.
Replacing the fuse: Only replace the fuse with the same type and rating.
Replacing the power cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers only
In order to avoid hazards.
Should you have further questions , please contact your dealer.
10
Parts List
1030-MPCB Main PCB Card
1030-DC-G Driver Card-gobo
1030-DC-P Driver Card-prism
1030-dis Display Card
9051 Dual Axis 250or 300 Case
1010FAN-S Lamp Fan 1.5X1.5
1030-IG Igniter
1030-PRISM Prism
1030-QRM Quick Release Mount Set
1010FAN Fan 3X3
1030-RF Reflector
LNSK250 JENDO NSK250/2
1030-TRA Transformer
P-1010IRF IR Filter
1030-PLLS Full Lens Set
LMSD250 Phillips MSD250/2
1030-DISB Display Body Set
1030-HEADB Head Body Set
1010-CBB65R Capacitor CBB65R
1030-MC Motor Color
1030-ARMB Arm Body Set
1030-MG Motor Gobo